Supports configurable input channels with different input type and range
High density 12-ch analog input solution for reading thermocouple sensor data
The AMAX-5000 analog input/output modules offers channel-independent configuration, signal type selection, and sensor wiring burn-out detection. AMAX-5018 Has Following Configuration. Channels: 6 differential Input Type: V, mV, Thermocouple Input Impedance: >2MΩ. Voltage Range: ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V. Temperature Range: Type J (-210 ~ 1200° C), Type K (-270 ~ 1372° C), Type T (-270 ~ 400° C), Type E (-270 ~ 1000° C), Type R (0 ~ 1768° C), Type S (0 ~ 1768° C), Type B (300 ~ 1820° C). Resolution: 16-bit with ±0.1% FSR accuracy. Sample Rage: 100 Sample/Second (per channel).